York model ycal chiller sensors
TABLE 1 EVAPORATOR COMPONENTS - 150 PSIG (SEE FIG. TABLES 1 AND 1A, PAGE 5)YORK INTERNATIONAL lbs Service Note: Standard 150# DWP Cooler Flow Switch - 024-26116-000 Optional 300# DWP Cooler Flow Switch - 024-12144-000 Differential Pressure Switch - 025-30919-000 (Optional)įIG. Pin location 38 in Model Number will be "3" for 300# DWP Cooler Plant of manufacture to include PIN 56 upon entering the chiller order.ĮVAPORATOR COMPONENTSService Note: Pin location 38 in Model Number will be "X" for 150# DWP Cooler. X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED 4. Panels (factory) : Acoustic Sound Blanket : Low Sound Fans : 1" Deection : Seismic : Neoprene Padsĥ5 EXTENDED FIELD WARRANTYX B C D E F G H: 1st Year Parts Only : 1st Year Parts & Labor : 2nd Year Parts Only : 2nd Year Parts & Labor : 5 Year Compressor Parts Only : 5 Year Compressor Parts & Labor Only : 5 Year Units Parts Only : 5 Year Unit Parts & Laborĥ6 REFRIGERANT WARRANTYX 1 2 5: No Refrigerant Warranty : 1 Year Refrigerant : 2 Year Refrigerant : 5 Year RefrigerantĦ1 PLANT OF MANUFACTUREB R: Basildon : Monterrey Panels (factory) : Louvered (Full Unit) Enc. Switch :ASME Pressure Vessel and Associated Codes :Remote CoolerĬONDENSER FIELD X C B P: Aluminum : Copper : Black Fin : Phenolic X : TEAO Fan MotorsĤ8 49 50 51 52 53 54CABINET FIELD X 1 3 5 7 B L 1 S N: Wire Condenser Headers Only (factory) : Wire (Full Unit) Enc. FIELD X 3 D W V S D A R :150# PSI DWP :300# PSI DWP :Double Thick Insulation :Weld Flange :Victaulic Flange :Flow Switch :Diff. : Suction TempSensor : Motor Current Module : OptiView Remote Panel S : Sequence Control & Automatic Lead Transferģ8 39 40 41 42 43 44EVAP.
York model ycal chiller sensors code#
American Safety Code (cU.L./cETL) : No Listing (typically 50 HZ non-CE, non-U.L. Reset / Offset B : ISN Microgateway : Spanish LCD & Keypad Display : French LCD & Keypad Display : German LCD & Keypad Display : Italian LCD & Keypad Display : : : N. # : No Ambient Kit T S : High Ambient Kit (factory) C : High Ambient Kit (eld) S : BAS/EMS Temp. Handles = Individual System Breaker & Lockable External Handle MP = Multiple Point SP = Single Point NF = Non-Fused TB = Terminal Block Ser. Brine (LBrT) :Thermal Storage :Chicago Relief Code :Service Isolation Valve :Both Chicago & Isolat. : SP NF Disconnect Switch : No Transformer Required : Transformer 115/24V (factory) : Special Transformer Required X : No Power Factor Capacitor C : Power Factor Capacitor Q : Special Power Factor CapacitorĢ0 21 22 23 24 25 26 27 28CONTROLS FIELD X H G T M S F G I L N T C OĢ9 30 31 32 33 34 35 36 37COMPRESSOR / PIPING FIELD:Low Temp. PART NUMBER LETTER CODES16 17 18 19POWER FIELD X M M S D X D B B B X T Q: Standard Power Option : MP NF Disconnect Switch : MP w/ Ind.
York model ycal chiller sensors series#
NOMINAL CAPACITY # Tons/Kw 0090 0094 0104 0114 0124 0134ĭESIGN/DEVELOPMENT LEVEL :Design Series C : :Engineering Change or PIN Level
UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATABASIC PART NUMBER Voltages as low as 50 volts may cause death.2YORK INTERNATIONAL LOW VOLTAGEDO NOT be misled by the term low voltage.
Be careful not to contact high voltage connections when installing or operating this equipment. When working inside equipment with power off, take care to discharge every capacitor likely to hold dangerous potential. Shut off power supply to the equipment before beginning work and follow lockout procedures. DEATH OR SERIOUS INJURY may result if personnel fail to observe safety precautions.Work on electronic equipment should not be undertaken unless the individual(s) have been trained in the proper maintenance of equipment and is (are) familiar with its potential hazards. HIGH VOLTAGE Is used in the operation of this equipment. 124 REMOTE CURRENT/TEMPERATURE RESET PARTS BREAKDOWN. 24 CHILLER OPTIONS YCAL CHILLER OPTIONS - KITS. 22 WIRE HARNESS CONNECTORS-FIELD REPLACEMENT PART NUMBERS. 20 TRANSDUCERS, PRESSURE CUTOUTS AND TEMP SENSORS. 12 CONTROL AND POWER PANELS CONTROL PANEL COMPONENTS.16 LUG KITS. 4 CONDENSER COILS CONDENSER COIL COMPONENTS. UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATA.
AIR-COOLED CONDENSING UNIT HERMETIC SCROLLRENEWAL PARTSSupercedes: 150.64-RP1 (904) Form: 150.64-RP1 (1105)